360 Secure SkillHub
360 安全技能中心

medical-device-reg-hub

面向医疗器械注册工程师的知识型资料库,按市场与注册阶段整理中国、美国、欧盟、日本及东南亚拉美等市场的注册路径、分类规则与专题要点,覆盖UDI、STED、生物相容性、GMP、风险管理、临床评价、上市后监管、标签IFU、供应商合规等方向,通过references目录下的Markdown枢纽文件提供要点与官方信息源指引,并可据此生成对比清单。

zhaoxinghua09-cell
zhaoxinghua09-cell
热度 52.54
最近更新 2026-10-17 09:05:22
分类:知识依赖:读写文件应用场景:研究 / 报告撰写 / 法律文档 / 模板

安装技能

复制下面的话术发给你的 Agent,它会通过 secure-skills 检索并安装该技能。

执行命令安装此 skill: npx secure-skills-cli add medical-device-reg-hub
Metadata
name
medical-device-reg-hub
displayName
医械注册工程师·全球通关枢纽
description
医疗器械注册工程师的「随身资料库」——中国 NMPA / 美国 FDA / 欧盟 MDR / 日本 PMDA 及东南亚·拉美全球注册路径与分类,UDI、STED 技术文件、生物相容性(ISO 10993)、GMP 质量体系、上市后监管、标签与 IFU、供应商合规 8 大枢纽要点 + 官方直达链接一站备齐。119 条官方链接已浏览器级逐条核验可达。
slug
medical-device-reg-hub
title
medical-device-reg-hub
version
1.1.1
author
SynomosAI
category
knowledge-management
description_zh
医疗器械注册工程师的「随身资料库」——中/美/欧/日及全球注册路径与分类、UDI/STED/生物相容性/GMP/上市后/标签IFU/供应商合规 8 大枢纽要点与官方直达链接一站直达。
description_en
All-in-one hub for medical device registration engineers — global pathways & classification (CN NMPA / US FDA / EU MDR / JP PMDA / ASEAN·LATAM), plus 8 topic hubs (UDI, STED, biocompatibility ISO 10993, GMP, post-market, labeling & IFU, supplier compliance) with verified official links.
read_when
["医疗器械注册工程师查全球路径与分类(NMPA/FDA/MDR/PMDA/东盟拉美)","UDI/STED/生物相容性/GMP/上市后/标签IFU/供应商合规等专题要点","跨市场注册周期、费用、证书有效期横向对比"]
agent_created
true
license
MIT
platforms
["cli"]
ai_protocol
true
spec
usk/1.0
interface
{"type":"prompt","entry_point":"SKILL.md","runtime":"none","call_pattern":"prompt"}
input_schema
{"args":{"type":"string","description":"CLI arguments per skill usage","required":false}}
output_schema
{"stdout":"structured result (JSON IR)","exit_code":"rc=0 ok / rc=1 warning / rc=2 bad input"}
capabilities
["medical-devices","regulatory","repository"]
permissions
{"network":false,"filesystem":false,"subprocess":false}
requirements
{"python_packages":[],"min_python":"3.8"}
changelog
1.1.1: Bilingual rewrite (full EN+ZH, English first); 1.1.0: initial upload (USK v3)

凡自治之物 · LGD 治理学 · 创造术家族 | 评测协议:skill-quality-gate

English

What this is

A structured knowledge hub for medical-device registration engineers. It consolidates regulations, standards, submission systems and templates from NMPA / FDA / EU MDR / PMDA and other markets into clickable official sources, organized by market × stage × product category. Covers the full flow: feasibility → classification & pathway → technical file → QMS → submission → review → post-market.

It ships 8+ topic hubs plus a global index and multi-market classification evidence: main index, UDI, STED writing, cycle-cost comparison, supplier compliance, GMP/validation, ISO 14971 risk, clinical evaluation, sterilization packaging, registration testing & submission practice, change/renewal, software/HF/IEC 62304, market access/sales, requirements & feasibility, design controls, after-sales, biocompatibility planning, post-market surveillance, labeling & IFU, and a 13-market real-certification classification evidence file for arthroscopic/basket/grasper forceps.

Why this hub

  • Conclusions are grounded in real registration certificates, not guesses; boundary cases are flagged "to verify".
  • Every point links directly to NMPA / FDA / EU MDR / PMDA / other official pages; conclusions are traceable.
  • Covers CN / US / EU / JP plus ASEAN & LATAM; 13-market comparison included.
  • 119 official links browser-verified on 2026-08-14; near-zero dead-link rate.
  • Maintained by a front-line medical-device international-registration practitioner.

Triggers

"medical device registration", "NMPA", "FDA 510(k)", "PMA", "De Novo", "MDR", "CE", "IVDR", "PMDA", "JMDN", "UDI", "STED", "eSTAR", "eRPS", "ISO 10993", "ISO 13485", "post-market", "IFU", "supplier compliance", "registration cycle/cost", or classification questions for specific products.

Workflow

  1. Determine intent: product classification / topic deep-dive / cross-market comparison.
  2. Load the most relevant references/ file (see navigation table) — never invent clauses or links from memory.
  3. Answer with the conclusion plus the official direct link.
  4. If the user wants a deliverable, generate Markdown / HTML comparison tables from references.
  5. Flag timeliness: key data points must be checked against the latest official release; unverified items marked "to verify".

Key facts (avoid common misjudgments)

  • CN: Class I = municipal filing; Class II = provincial registration; Class III = NMPA central. Reusable arthroscopic forceps usually Class II (provincial); open/non-sterile plain forceps Class I.
  • US FDA: 21 CFR 888.1100(b)(2) product code HRX — basic reusable manual arthroscopic forceps/graspers are Class I, 510(k)-exempt; only variants with special function / sterile single-use / advanced claims are Class II 510(k).
  • EU MDR: reusable surgical instruments per Rule 6 are usually Class I (self-declaration + CE); sterile/measuring/software variants need a Notified Body.
  • JP PMDA: structure classes (general I / controlled II / highly controlled III·IV) are correct; "most reusable manual arthroscopic forceps are Class I" is inference — verify by JMDN code (e.g. 361030) on PMDA; flagged to-verify.
  • ASEAN/LATAM: bands are correct (Thai FDA lists reusable surgical instruments as Class 1 = ASEAN class A); country details vary.

Boundary

  • This is a curated index of public official information; it is NOT a regulatory opinion.
  • Classification of boundary products should go through official classification-determination procedures.
  • Do not fabricate clauses or links; always cite references.

Evidence & safety

  • Evidence: TBD. Version: 1.1.1. Security: see package security snapshot; no independent external scan.

中文

这是什么

医疗器械注册工程师的结构化资料枢纽。把分散在 NMPA / FDA / EU MDR / PMDA 及各市场官网的法规、标准、申报系统、模板,按「市场 × 注册阶段 × 产品类别」整理成可点击直达的官方源。覆盖从产品立项 → 分类与路径 → 技术文件 → 质量体系 → 注册申报 → 审评获批 → 上市后的全流程。

内置 8 大专题枢纽 + 1 份全球注册索引 + 1 份多市场分类实证:主索引、UDI、STED 撰写、周期费用对比、供应商合规、GMP 质量体系与验证、ISO 14971 风险管理、临床评价、灭菌包装验证、注册检验与申报实操、变更延续管理、软件人因(IEC 62304 / SaMD / 网络安全)、市场准入与销售、需求调研与立项、设计开发控制、售后服务、生物相容性规划、上市后监管、标签与 IFU,以及篮钳/剪线钳/过线钳 13 市场真实注册证验证的分类实证。

为什么用这个枢纽

  • 不是泛泛而谈,是「真实注册证验证过」的结论:不做拍脑袋推断;边界情形明确标注"待核验 / 走分类界定"。
  • 官方源一站直达:每个要点都附带 NMPA / FDA / EU MDR / PMDA / 各国官网直达链接,结论可溯源、可复核。
  • 覆盖中 / 美 / 欧 / 日 + 东南亚·拉美:从单一市场到 13 国横向对比都有。
  • 链接已逐条核验:references 内 119 条官方链接于 2026-08-14 经浏览器级复核,死链率趋近于零。
  • 作者即从业者:由医疗器械国际业务一线(熟悉 GMP / NMPA 法规、海外报证)整理维护。

触发场景

当用户提到以下任意内容时,优先加载本技能并从 references/ 调取对应资料:

  • "医疗器械注册" / "医械注册" / "注册工程师"
  • "NMPA" / "FDA 510(k)" / "PMA" / "De Novo" / "MDR" / "CE" / "IVDR" / "PMDA" / "JMDN"
  • "UDI" / "唯一标识" / "发码机构"
  • "STED" / "技术文件" / "注册资料" / "eSTAR" / "eRPS"
  • "生物相容性" / "ISO 10993" / "GB/T 16886"
  • "GMP" / "ISO 13485" / "QSR" / "QMSR" / "工艺验证" / "再处理验证"
  • "上市后" / "不良事件" / "召回" / "PMS" / "FSCA"
  • "标签" / "IFU" / "说明书"
  • "供应商合规" / "13485 证书" / "材质证明"
  • "注册周期" / "注册费用" / "证书有效期" / "注册路径"
  • "全球注册" / "中国/美国/欧盟/日本/东南亚/拉美 注册"
  • 具体产品如"关节镜钳" / "腔镜器械" / "取石网篮" 的注册分类与路径问题

使用流程

  1. 判断意图:某产品的分类/路径、某专题要点、还是跨市场对比?
  2. 加载对应资料:从 references/ 读取最相关的文件,不凭记忆编造法规条文或链接。
  3. 给结论 + 官方源:每个结论附 references 中的官方直达链接。
  4. 生成交付物:若用户要"做成资料/网页/清单",基于 references 内容生成 HTML / Markdown 交付物。
  5. 标注时效与边界:法规/标准会更新,关键数据提示以官方最新发布为准;未逐码验证条目标"待核验"。

references/ 文件导航

用户问题类型 加载文件
整体注册路径/多市场索引 注册工程师资料枢纽.md
具体产品分类与全球路径实证 篮钳剪线钳过线钳_全球注册路径汇编.md
UDI 相关问题 UDI全球标识枢纽.md
技术文件/STED 撰写 技术文件STED撰写枢纽.md
周期/费用/有效期对比 注册周期费用有效期对比枢纽.md
供应商/材质合规 原材料供应商合规枢纽.md
GMP/质量体系/验证 GMP质量体系与验证枢纽.md
风险管理/ISO 14971 风险管理枢纽.md
临床评价/同品种/CER 临床评价枢纽.md
灭菌/无菌包装/SAL 灭菌包装验证枢纽.md
注册检验/申报/eRPS/eSTAR 注册检验与申报实操枢纽.md
变更/延续/807.81 变更延续管理枢纽.md
软件/SaMD/网络安全/人因 软件人因枢纽.md
市场准入/出口销售/经营许可/集采 市场准入与销售枢纽.md
需求调研/立项/PRD/设计输入 需求调研与立项枢纽.md
设计开发/设计控制/DHF 设计开发控制枢纽.md
售后/投诉/维修/备件 售后服务枢纽.md
生物相容性规划 生物相容性测试规划枢纽.md
上市后/PMS/召回 上市后监管枢纽.md
标签/IFU 标签与IFU枢纽.md

关键事实速查

  • 中国:境内Ⅰ类市局备案,Ⅱ类省局注册,Ⅲ类国家局;进口Ⅱ/Ⅲ类国家局。关节镜用钳(腔镜、无菌)多归 Ⅱ类(省局);开放/非无菌普通钳归 Ⅰ类(市局备案)。
  • 美国 FDA:21 CFR 888.1100(b)(2)(产品代码 HRX)将基础手动复用型关节镜 forceps/graspers/suture passers 列为 Class I、豁免 510(k);仅带特殊功能/无菌一次性/进阶宣称的变体才归 Class II 510(k)。
  • 欧盟 MDR:可重复使用外科器械按 Rule 6 多归 Class I(自我声明 + CE);无菌/测量/带软件等才需公告机构介入。
  • 日本 PMDA:结构(一般Ⅰ/管理Ⅱ/高度管理Ⅲ·Ⅳ)正确,但"多数复用手动关节镜钳为 I 类"系推断,须按具体 JMDN 编码在 PMDA 查实,标注 ⚠️ 待核验。
  • 东南亚/拉美:区间正确(泰国 Thai FDA 明确"可重复使用手术器械"= Class 1 = ASEAN A 类);具体国家略有差异,以各国官网为准。
  • 官方链接有效性:FDA/ISO 站点 bot 探测常返 404/403(反爬),但浏览器可正常打开;判定链接是否有效必须以浏览器级核验为准。

能力边界

  • 不替代法律/监管意见:本技能汇总公开法规要点与官方源索引,正式合规决策以官方最新发布与专业顾问为准。
  • 时效声明:法规/标准会更新,关键数据以官方最新版本为准;对未逐码核验的条目明确标注"待核验"。
  • 不编造:结论附 references 中的官方直达链接,不凭记忆编造法规条文或链接。

证据与安全声明

  • 证据:见包内 ATTESTATION.md、manifest.json 与 security_results.json(2026-10-16 读取)。
  • 版本:1.1.1
  • 安全:本地闭环 / 零凭据 / 去敏扫描 / 版权三件套 / 权属五件套 / 文档一致性 / 结构完整 / 可重跑性 8 项均 5 分,sensitive_hits=[];另见包内 ATTESTATION.md。