360 Secure SkillHub
360 安全技能中心

Shelly Plug S Gen3

为 Shelly Plug S Gen3 智能插座定义设备契约:规范 telemetry.switch_status 遥测字段与 command.switch.set 命令载荷及校验,映射本地 Shelly JSON-RPC 方法,并给出主代理与桥接代理的职责边界与安全约束。

eduv09
eduv09
热度 19.20
最近更新 2026-07-21 20:54:55
分类:自动化依赖:第三方 API应用场景:API 集成 / 工作流 / 自动化脚本

安装技能

复制下面的话术发给你的 Agent,它会通过 secure-skills 检索并安装该技能。

执行命令安装此 skill: npx secure-skills-cli add smartclaws-device-shelly-plug-s-gen3
Metadata
name
smartclaws-device-shelly-plug-s-gen3
description
Device contract for Shelly Plug S Gen3. Defines SmartClaws topics, payloads, local Shelly RPC methods, and safety rules for bridge and master agents.
license
LGPL-3.0-or-later
metadata
{"openclaw":{"emoji":"🔌","homepage":"https://github.com/skalenetwork/smartclaws","requires":{"config":["plugins.entries.smartclaws"]}}}

Shelly Plug S Gen3 Device Contract

This is a device contract skill. It does not install SmartClaws, register a device, or define an agent role. Use it with smartclaws-master-agent or smartclaws-bridge-agent.

Device Identity

  • Vendor: Shelly
  • Device: Shelly Plug S Gen3, Type F variant
  • Capability: one relay switch channel with built-in power metering
  • Local protocol: Shelly Gen2+/Gen3 JSON-RPC over HTTP
  • Controllable component: switch:0

SmartClaws Channels

The setup must provide channel addresses in SMARTCLAWS.md.

  • Outgoing telemetry channel: required.
  • Incoming command channel: required only for commandable setups.

Do not invent channel addresses. If a channel is missing, ask for setup.

Telemetry Topic

Topic: telemetry.switch_status

Normalized payload:

{
  "output": true,
  "apower_w": 852.3,
  "voltage_v": 230.1,
  "current_a": 3.7,
  "energy_total": 142.4,
  "temperature_c": 41.5
}

Fields:

  • output: relay state, true = ON, false = OFF.
  • apower_w: active power in watts.
  • voltage_v: mains voltage.
  • current_a: current draw in amps.
  • energy_total: cumulative energy value reported by Shelly.
  • temperature_c: plug internal temperature in Celsius; not room temperature.

Shelly RPC source mapping:

  • output <- Switch.GetStatus?id=0.output
  • apower_w <- apower
  • voltage_v <- voltage
  • current_a <- current
  • energy_total <- aenergy.total
  • temperature_c <- temperature.tC

Command Topic

Topic: command.switch.set

Payload:

{
  "on": true,
  "toggle_after": 0
}

Validation:

  • on is required boolean.
  • toggle_after is optional non-negative integer seconds.
  • toggle_after: 0 means no auto-revert.
  • Reject strings, floats, negative values, null, and unknown command topics.

Effect:

  • on: true maps to relay ON.
  • on: false maps to relay OFF.

Local RPC Methods

Read device info:

GET /rpc/Shelly.GetDeviceInfo

Read relay/power state:

GET /rpc/Switch.GetStatus?id=0

Set relay state:

GET /rpc/Switch.Set?id=0&on=true
GET /rpc/Switch.Set?id=0&on=false

If authentication is enabled, the bridge setup must provide the credential path or mechanism. Do not print credentials.

Master-Agent Use

A master may:

  • Read telemetry.switch_status from the outgoing channel.
  • Decide whether a command is needed.
  • Publish command.switch.set only when setup authority allows it. With the SmartClaws plugin, use smartclaws_publish with the registered device name and deviceChannel: "command" so the write goes through SmartClawsDevice.publishCommand.

A master must not:

  • Call Shelly RPC directly.
  • Treat plug internal temperature as room temperature.
  • Re-send commands repeatedly without checking recent telemetry/decision state.

Bridge-Agent Use

A bridge may:

  • Read Shelly RPC status and publish telemetry.switch_status.
  • In command-enabled modes, read command.switch.set from the incoming channel and call Switch.Set.
  • Persist the last handled command offset in its setup state file.

A bridge must not:

  • Execute unknown command topics.
  • Reprocess already-handled command offsets.
  • Publish fake telemetry unless explicitly running a labelled simulation.

Sanity Rules

  • output must be boolean.
  • Power, voltage, current, energy, and temperature must be numeric when present.
  • Missing optional numeric fields may be omitted; do not invent values.
  • If Shelly is unreachable, publish no telemetry for that cycle and log/fail loud.