NovaPM SDS011 Device Contract
This is a device contract skill. It does not install SmartClaws or define an
agent role. Use it with smartclaws-bridge-agent for publishing telemetry and
with smartclaws-master-agent for reading/auditing air-quality data.
Device Identity
- Device family: NovaPM using the SDS011 particulate matter sensor.
- Capability: read PM2.5 and PM10 concentrations.
- Local protocol: SDS011 serial protocol over USB serial.
- Default port in existing setups:
/dev/ttyUSB0. - Default warmup in existing setups:
30seconds; never below15seconds. - Actuation: none. This is telemetry-only hardware.
SmartClaws Channels
The setup must provide channel addresses in SMARTCLAWS.md.
- Outgoing telemetry channel: required.
- Incoming command channel: must be null/absent. SDS011 receives no SmartClaws commands.
Do not invent channel addresses.
Telemetry Topic
Topic: telemetry.air_quality
Payload:
{
"pm25_ug_m3": 12.3,
"pm10_ug_m3": 28.1,
"sensor": "sds011",
"port": "/dev/ttyUSB0",
"ts": "<current ISO 8601 UTC>"
}
Fields:
pm25_ug_m3: PM2.5 concentration in micrograms per cubic meter.pm10_ug_m3: PM10 concentration in micrograms per cubic meter.sensor: should besds011for this contract.port: serial port used for the reading.ts: ISO 8601 UTC timestamp for the reading.
Command Topics
None. This device is read-only.
If a setup provides an incoming channel or command topic for this device, treat it as a setup error unless an operator explicitly changes the device contract.
Bridge-Agent Use
A bridge should:
- Wake the sensor.
- Wait the configured warmup duration.
- Read one valid measurement frame.
- Put the sensor back to sleep.
- Validate the values.
- Publish
telemetry.air_qualityto the outgoing channel withsmartclaws_publish. - Log failures instead of publishing bad data.
The bridge should preserve sensor life. Avoid unnecessarily short polling intervals; existing setup guidance used a 5-minute cadence with a 30-second warmup.
Master-Agent Use
A master may:
- Read
telemetry.air_qualityfrom the outgoing channel. - Answer air-quality/status questions.
- Use readings as context for broader decisions.
- Log threshold or stale-data decisions to its own decision channel.
A master must not publish commands to this device.
Sanity Rules
Reject a reading and publish no telemetry when:
pm25_ug_m3 < 0orpm25_ug_m3 > 1000.pm10_ug_m3 < 0orpm10_ug_m3 > 1000.pm25_ug_m3 > pm10_ug_m3, which is physically inconsistent for this sensor.- The sensor returns no valid frame after warmup.
Do not repair, smooth, or invent readings. Bad data is worse than no data.
Human Interpretation
When reporting readings to a person, include raw values and a plain label.
The bands and thresholds below are non-authoritative display reference (drawn
from common EU/EPA/WHO levels) — they help you label a reading, not decide policy.
Actual alert thresholds and what to do about them are the owner's call and
belong in AGENTS.md, not this device contract. Reference only:
- PM2.5 high (EU/EPA alert ≈
35µg/m³; WHO 24h guideline is15). - PM10 high (EU/EPA alert ≈
50µg/m³; WHO 24h guideline is45).
Useful context labels:
- Good: PM2.5
0-5, PM100-20. - Moderate: PM2.5
5-15, PM1020-45. - Elevated: PM2.5
15-35, PM1045-50. - High: PM2.5
>35, PM10>50.
Always check the timestamp. If the latest reading is older than the expected publish cadence, say the data may be stale.